Eaton XDT1A3 resin encapsulated dry-type transformer for hazardous areas

Technical Specification

Features:
  • Make: Eaton
  • Model code: XDT1A3
  • Type: Dry-type transformer
  • Unit ratings or power ratings: 3 kVA
  • Primary Voltage: 480V
Read more
Additional info:

Resin encapsulated core coil assembly for reliable performance in extreme environments NEMA 3R, 4 and 4X enclosures provide essential ingress protection 180°C insulation system with 115°C or 95°C winding temperature rise creates optimal loading capabilities Removable hinged door for front access to wiring compartment (XTT only) Custom configurations available to meet customer specifications

Read more
Make Eaton
Manufacturer Eaton
Category Transmission and Distribution>Transformers
Model code XDT1A3
Type Dry-type transformer
Unit ratings or power ratings 3 kVA
Primary Voltage 480V
Secondary Voltage 208Y/120V
Frequency range 60 Hz
No. of Phases Single-phase
Standards/Approvals UL1604, UL5085-1, UL5085-2 / NEMA 3R, 4,4X
Winding material Aluminum or Copper
Installation Indoor / Outdoor

Product description

The Eaton XDT1A3 transformer is part of the XDT series of resin encapsulated dry-type transformers, specifically engineered for hazardous area power distribution. With a robust design tailored for environments where volatile flammable liquids or gases are handled, the XDT1A3 ensures safe and efficient electrical performance.

Key Features

  • Resin encapsulated core coil assembly, offering reliable performance in severe environments.
  • NEMA 3R and 4X enclosures providing crucial protection against environmental ingress.
  • 180°C insulation system with a 115°C winding temperature rise, optimizing load capacities.
  • Customizable configurations to meet specific industry requirements.

Technical Specifications

  • Single-phase with a power rating of 3 kVA.
  • Primary voltage: 480V, Secondary voltage: 208Y/120V.
  • 60 Hz frequency with an impedance range of 1.8% to 6.5%.

Certifications and Compliances

  • Class I, Division 2, Groups A, B, C, D certification.
  • cUL to C22.2 No. 66 and C22.2 No. 213-M1987 compliance.
  • UL Standards: UL1604, UL5085-1, UL5085-2.

Ideal Use Cases

Perfectly suited for refineries, chemical and petrochemical plants, mining operations, and corrosive process facilities, the Eaton XDT1A3 excels in both indoor and outdoor industrial applications. Its rugged construction also makes it ideal for offshore platforms and other harsh environment installations.