Download PDF version

Many times, when specifying replacement switches I&E technicians may feel most comfortable replacing “like-with-like”, and stick with a mechanical switch.

Users may be acclimated toward electromechanical switch maintenance and may not be fully aware of the hidden maintenance costs vs. those associated with an electronic switch serving the same function.

Electromechanical switches 

Electromechanical switches are built from an array of moving parts including mechanical switch contacts, adjustment screws, plungers, springs, and more, leaving little room for error before a switch fails. 

Many ways a switch can fail include, but are not limited to sticking parts due to media buildup; shifting set point adjustments from vibration or temperature changes; or contact corrosion over time.

Regular maintenance

If a permanent failure occurs, then the replacement of the mechanical switch will include costly downtime

Regular maintenance is required to detect these issues. These maintenance hours can be costly and multiplied by the number of mechanical switches present at a site, add up quickly.

If a permanent failure occurs, such as corroded contacts, then the replacement of the mechanical switch will include costly downtime in addition to the maintenance hours.

Electronic switches

Electronic switches, on the other hand, do not contain any moving parts that wear over time, and since all set point adjustments are programmed electronically, calibration is less affected by vibration and temperature changes. Also, contact corrosion is no longer a concern because there are no physical contacts in electronic switches that use a solid-state relay.

And with smart, electronic switches, if faults do occur, the display will show an error code explaining which error had been detected. This identifies the specific device with the problem and identifies what the I&E technician needs to fix to reverse the fault and get the switch operational.

ONE Series

The user would install a mechanical dampener with an electromechanical switch, to prevent these false trips

United Electric Controls’ ONE Series smart, electronic switch can help keep maintenance and costs to a minimum. Pressure spikes can often cause erroneous setpoint trips. These unwanted trips interrupt the process and might even trigger maintenance requests.

Typically, the user would install a mechanical dampener in line with their electromechanical switch, to prevent these false trips. An I&E technician needs to maintain two mechanical products.

Features

One of the features of the ONE Series smart, electronic switch is the Filter mode that will electronically dampen pressure spikes to prevent any erroneous trips. This is now achieved with one device and saving the maintenance on two mechanical devices.

There are other maintenance-friendly features included, such as Plugged Port mode and Window mode. In conclusion, there are many ways upgrading to the ONE Series could help cut unnecessary, hidden maintenance costs when using electromechanical switches, and in addition, increase reliability and performance efficiencies.

Download PDF version Download PDF version

In case you missed it

Karenann Terrell Joins Eaton Board, Boosting Digital Expertise
Karenann Terrell Joins Eaton Board, Boosting Digital Expertise

Intelligent power management company Eaton announces that Karenann Terrell has been elected to the company’s Board of Directors effective July 24, 2024. Terrell is the retir...

EPSRC Funds Cutting-Edge Semiconductor Research At Surrey
EPSRC Funds Cutting-Edge Semiconductor Research At Surrey

A brand-new 1.25 million volts (MV) implanter will spark cutting-edge research and innovation in semiconductor and quantum technologies, say scientists at the University of Surrey....

Eaton Recognized For Disability Inclusion Across Three Countries
Eaton Recognized For Disability Inclusion Across Three Countries

Intelligent power management company Eaton announced its commitment to inclusive strategies and programming for people with disabilities and has earned high scores on three Disabil...

vfd