Eaton C30CNM48A02A0 Mechanically Held Lighting Contactor
Technical Specification
- Make: Eaton
- Model code: C30CNM48A02A0
- Series: C30CN mechanically held lighting contactors
- No. of Poles: 12
- Rated Voltage: 115 ~ 120 V 60 Hz / 110 V 50 Hz
Two-wire mechanically held lighting contactor 30 A power pole rating Low magnetic noise results in quiet operation Low input VA permits long wire runs An ideal solution for controlling tungsten (incandescent filament), ballast (fluorescent and mercury arc), high intensity discharge (HID), non-motor AC resistive and single- & three phase motor ratings load Provides effective control in applications such as office buildings, industrial plants, hospitals, stadiums, airports, and so on
Read more| Make | Eaton |
|---|---|
| Manufacturer | Eaton |
| Category | Motors and Electrical Equipment>Contactors |
| Model code | C30CNM48A02A0 |
| Series | C30CN mechanically held lighting contactors |
| No. of Poles | 12 |
| Rated Voltage | 115 ~ 120 V 60 Hz / 110 V 50 Hz |
| Rated Current | 30 A |
| Enclosure | Open |
| Standards | UL |
| Height | 3.86 inch |
| Depth | 7.39 inch |
| Width | 4.18 inch |
Product description
Eaton C30CNM48A02A0 Lighting Contactor
The Eaton C30CNM48A02A0 is a 30A lighting contactor designed for efficient control in industrial, commercial, and outdoor lighting environments. Engineered for mechanically held operation, it ensures the contactor remains in the ON position even during control power failures, eliminating risks related to unexpected power interruptions.
Key Features
- Versatile Application: Suitable for controlling tungsten (incandescent), ballast (fluorescent and mercury arc), and high-intensity discharge (HID) loads, as well as non-motor AC resistive loads.
- Quiet Operations: Quiet, noise-free operation due to the removal of the coil from the circuit once the contactor is latched.
- Robust Construction: The contactor's robust design includes low magnetic noise and a wide range of input voltages, supporting coils from 24Vac to 277Vac.
- Efficient Control: Utilizes a control module microprocessor to verify control signals, preventing operation in response to transient voltage spikes.
- Delayed Command Execution: Features a 0.4 second built-in operation command delay, mitigating risks of contact fatigue due to repetitive commands.
- Feedback Loop: A feedback loop ensures the contactor does not become desynchronized with switches, even after power outages.
Ideal Use Cases
The Eaton C30CNM48A02A0 is ideal for applications requiring quiet and energy-efficient operation, such as office buildings, industrial plants, hospitals, stadiums, and airports. It is particularly useful in environments where maintaining operational continuity during power failures is critical.
- See other Eaton products
- Eaton Safety Switches and Disconnects
- Eaton Busway
- Eaton Transformers
- Eaton Circuit Breakers and Fuses
- Eaton Cable Tray